Paclitaxel Set, 0.22 Micron Downstream High Pressure Filter, CLEARLINK Luer Activated Valve, 10GTT, L107″ – Baxter
$1,303.80
Secure Encrypted Checkout
Need Help?
Description
Paclitaxel Set with 0.22 Micron Downstream High Pressure Filter and CLEARLINK Luer Activated Valve, 10GTT, L107″ (Baxter)
The Baxter Paclitaxel Set is an IV administration set designed for the delivery of paclitaxel therapy using appropriate filtration and needle-free access components. Built for compatibility with standard infusion systems, this set integrates a downstream 0.22 micron high pressure filter and a CLEARLINK luer activated valve to support controlled medication administration and secure, closed-system access. The 107-inch tubing length (L107″) provides reach for common infusion setups, and the 10 drops/mL drip rate (10GTT) supports macrodrip gravity infusion workflows where applicable.
Intended use
This IV set is intended for administering paclitaxel infusion in clinical environments where a downstream 0.22 micron filter and a luer activated valve are required per facility protocol. It is used as part of an infusion line between the fluid container and the patient access device, as configured by the clinician.
Key components
- 0.22 micron downstream filter designed to filter the infusate close to the patient side of the line, supporting particulate and microbial retention consistent with 0.22 micron filtration practices.
- High pressure filter housing intended to tolerate higher line pressures that may be encountered with infusion equipment and occlusion conditions, per manufacturer specifications.
- CLEARLINK luer activated valve needle-free access point that opens upon connection with a compatible luer device, helping support a closed system and reducing the need for needles.
- Macrodrip chamber (10GTT) calibrated at 10 drops/mL for gravity-based flow rate calculation when used in that mode.
- 107-inch tubing length supports routing from IV pole to pump or patient access site with flexibility for typical bedside layouts.
Clinical workflow benefits
By combining a downstream 0.22 micron filter with a needle-free valve, the set helps streamline paclitaxel administration where filtration and closed access are desired. Downstream placement keeps filtration nearer the patient connection, while the luer activated valve supports connection of compatible syringes or extension components without exposed needles. The macrodrip chamber can assist clinicians who use drip counting for setup verification or gravity infusion, while remaining compatible with common infusion configurations per institutional policy.
Specifications
| Attribute | Value |
|---|---|
| Product type | IV administration set and accessories |
| Therapy | Paclitaxel infusion |
| Filter | 0.22 micron downstream, high pressure |
| Valve | CLEARLINK luer activated valve |
| Drop factor | 10 drops/mL (10GTT) |
| Tubing length | 107 inches (L107″) |
| Manufacturer | Baxter |
Handling and compatibility notes
Use only by trained healthcare professionals and according to facility protocol, paclitaxel labeling, and Baxter instructions for use. Prime, connect, and operate the set using aseptic technique and verify compatibility of all luer connections, pumps, and access devices prior to infusion. Replace and dispose of the set per institutional policy and applicable regulations.