cobas b 101 Lipid Panel Control 1ML 2-L1 2-L2 – Roche Diagnostics
$280.20
Secure Encrypted Checkout
Need Help?
Description
cobas b 101 Lipid Panel Control 1 mL (2-L1, 2-L2) – Roche Diagnostics
The cobas b 101 Lipid Panel Control 1 mL (2-L1, 2-L2) from Roche Diagnostics is a dedicated quality control material designed for use with the cobas b 101 system to support routine performance verification of lipid panel testing. As part of the Instruments and Equipment category, this control helps laboratories and near-patient testing environments monitor analytical stability and maintain confidence in reported results by providing two control levels in a convenient kit configuration.
This product includes control materials intended to simulate patient-like samples across clinically relevant ranges, enabling users to assess the measurement process for lipid-related parameters typically reported on the cobas b 101 lipid panel. The two levels—commonly referenced as Level 1 (L1) and Level 2 (L2)—are used to check system performance at different concentration points, supporting internal quality control practices and helping identify shifts or trends that may affect accuracy and precision.
Key Features
- Two-level control set: Includes 2 x Level 1 (L1) and 2 x Level 2 (L2) to support multi-level QC assessment.
- 1 mL format: Practical vial size designed for routine QC scheduling and efficient utilization.
- System-matched: Formulated for compatibility with the cobas b 101 system lipid panel workflow.
- Quality assurance support: Helps verify day-to-day instrument and reagent performance and supports consistent reporting.
- Operational confidence: Enables detection of potential analytical issues such as drift, imprecision, or calibration-related changes.
Intended Use
The cobas b 101 Lipid Panel Control is intended for in vitro diagnostic quality control use with the cobas b 101 system. It is used to monitor the performance of lipid panel measurements by running control materials in accordance with the laboratory’s QC policy, applicable regulations, and the instrument’s instructions for use. Control testing is typically performed at defined intervals, such as at the start of a shift, with new reagent lots, after maintenance, or whenever performance concerns arise.
Typical Applications
- Routine internal quality control for cobas b 101 lipid panel testing
- Verification following instrument maintenance or troubleshooting
- Lot-to-lot checks when changing reagents or consumables
- Ongoing monitoring to support quality management programs
Product Configuration
| Attribute | Details |
|---|---|
| Product name | cobas b 101 Lipid Panel Control |
| Manufacturer | Roche Diagnostics |
| Fill volume | 1 mL per vial |
| Levels included | 2 x L1 and 2 x L2 |
| Use | IVD quality control material for cobas b 101 lipid panel |
Handling and Storage
Store, prepare, and use the control material exactly as specified in the Roche cobas b 101 Lipid Panel Control instructions for use. Follow all applicable laboratory safety procedures and quality system requirements. Record control results, review against established acceptance criteria, and investigate out-of-range findings before reporting patient results.
Note: This quality control product is not intended for diagnostic use as a patient sample. Compatibility and acceptable ranges depend on the cobas b 101 system configuration and Roche documentation for the specific control lot.




