Blood Transfusion Set, Non-Vented, for Alaris Pump Module
The Blood Transfusion Set, Non-Vented, for Alaris Pump module is a sterile, single-use administration set designed to deliver compatible blood components through the Alaris infusion pump module with controlled, consistent flow. Built for clinical transfusion workflows, this set supports safe, efficient connection between the blood component container and the patient access device while maintaining a closed, non-vented fluid path. It is intended for use by trained healthcare professionals in accordance with institutional policy, applicable standards, and the Alaris pump module Instructions for Use (IFU).
This non-vented configuration is intended for use with flexible blood bags and other collapsible containers that do not require air admission for infusion. By eliminating a vent, the set helps preserve a closed system and reduces the risk of airborne contamination pathways associated with vented administration. The set incorporates features appropriate for blood administration, including filtration to help remove clots and aggregates in accordance with common transfusion practice and facility protocols.
Key Features
- Non-vented design for use with collapsible blood containers and closed-system transfusion setups.
- Compatibility with the Alaris Pump module for pump-regulated delivery and standardized setup.
- In-line blood filter to support removal of micro-aggregates and clots per transfusion requirements.
- Sterile, single-use construction to support infection control and reduce cross-contamination risk.
- Clear tubing to aid visual monitoring of priming, flow, and presence of air or particulate.
- Secure connections designed to maintain leak-resistant performance when assembled correctly.
Clinical Use
This set is used for administration of blood and blood components as permitted by local policy, such as packed red blood cells and other compatible components that require filtration and controlled delivery. It is suited to acute care environments where pump-based infusion is preferred for precision, documentation, and standardized operation. The set is intended to be primed and loaded per the Alaris pump module IFU, ensuring the tubing is correctly positioned for accurate pumping action and alarm functionality.
As with all transfusion devices, appropriate patient identification, product verification, and monitoring are required. Flow rate, pressure limits, and alarm settings should be configured in accordance with clinical judgment and institutional protocols. Do not use this non-vented set with rigid containers that require venting unless a suitable venting solution approved by the facility and manufacturer is employed.
Typical Components
- Patient line and pump segment configured for the Alaris Pump module
- Drip chamber and in-line blood filter assembly
- Standard connectors for bag access and patient access (as supplied)
- Clamps and access points as provided for setup and priming
Handling, Storage, and Safety Notes
- Use only if the package is intact, within expiration, and the set is undamaged.
- Single patient use only; do not reprocess or reuse.
- Prime using an approved compatible solution and follow facility priming procedures to minimize air.
- Verify compatibility with the Alaris Pump module model and the blood component container type.
- Follow transfusion standards for maximum hang time and set change intervals.
The Blood Transfusion Set, Non-Vented, for Alaris Pump module supports reliable pump-based transfusion with a closed, non-vented pathway and blood-appropriate filtration, helping clinicians deliver therapy with confidence and consistency.